Kit testare apa acvariu ATI ICP-OES Water Analysis - Analiza Completa Apa ICP ATI
|
Parameter |
ATI® Laboratory Analysis Standard |
ATI® Laboratory Analysis Pro |
ATI® Laboratory Analysis Ultimate MS |
|
Salinity |
✓ ICP-OES |
✓ ICP-OES |
✓ ICP-OES |
|
Major Elements (without Fluorine) |
✓ ICP-OES (high accuracy) |
✓ ICP-OES (high accuracy) |
✓ ICP-OES (high accuracy) |
|
OES Trace Elements
|
✓ ICP-OES (medium detection limits) |
✓ ICP-OES (medium detection limits) |
✓✓ Double Validation through ICP-OES & ICP-MS (extremely low detection limits down to the ultra-trace range) |
|
OES Pollutants |
✓ ICP-OES (medium detection limits) |
✓ ICP-OES (medium detection limits) |
✓✓ Double Validation through ICP-OES & ICP-MS (extremely low detection limits down to the ultra-trace range) |
|
Phosphate/ Phosphorus |
✓ ICP-OES (high accuracy) |
✓ ICP-OES (high accuracy) |
✓ ICP-OES (high accuracy) |
|
Nitrate and Fluorine |
X |
✓ Ion Chromatography |
✓ Ion Chromatography |
|
Alkalinity (Carbonate Hardness) |
X |
✓ Titration |
✓ Titration |
|
Analysis of RO Water |
X |
✓ ICP-OES (high accuracy) |
✓ ICP-OES (high accuracy) |
|
MS Trace Elements*
|
X |
X |
✓ ICP-MS (extremely low detection limits down to the ultra-trace range) |
|
MS Pollutants* |
X |
X |
✓ ICP-MS (extremely low detection limits down to the ultra-trace range) |
|
Summary |
Solid basic laboratory analysis for the price-conscious user |
Comprehensive laboratory analysis with all important parameters |
Comprehensive laboratory analysis including consideration of all pollutants and ultra-trace elements |
The parameters from the table include the following:
- Salinity in PSU
- Alkalinity / Carbonate Hardness
- Nutrients: nitrogen/nitrate, phosphorus/phosphate
- Major elements: sodium, calcium, chloride, magnesium, sulfur, potassium, bromine, strontium, boron, fluorine
- OES trace elements: barium, beryllium, iron, iodine, lithium, molybdenum, silver, silicon
- OES pollutants: aluminum, antimony, bismuth, cadmium, lanthanum, thallium, titanium, tungsten
- MS trace elements*: Arsenic, chromium, cobalt, copper, manganese, nickel, rubidium, selenium, vanadium, zinc, tin
- MS pollutants*: Lead, neodymium, niobium, zirconium, indium, germanium, gallium, mercury, tellurium
*MS trace elements and MS pollutants – elements that can only be measured with ICP-MS in very low but physiologically already effective concentrations
How to do an ATI® Laboratory Analysis:
- Register at lab.atiaquaristik.com, create an aquarium profile, and scan the QR code to activate the Laboratory Analysis.
- Fill the sample tube with aquarium water (and reverse osmosis water, if applicable).
- Apply the barcodes and send them to the specified return address.
- You will receive status updates and results via email.
ATI Lab este un serviciu de testare a apei din acvariu care masoara 43 de parametri de apa diferiti utilizand computerul ARCOS II ICP-OES (Plasma cuplata inductiv - Spectrometrie de emisie optica) impreuna cu alte doua tehnici de testare pentru a va oferi o analiza completa si cuprinzatoare a apei. Kitul contine 4 eprubete pentru a testa atat apa RO, cat si apa din acvariu pentru o analiza completa la un pret incredibil.
Singurul kit care vine cu livrare retur, astfel incat nu exista costuri suplimentare pentru testare.
Acest kit va masura:
Salinitatea si valoarea KH
Deoarece toate citirile sunt afectate de salinitate, acest lucru va ofera citiri echilibrate si precise, cu certitudine completa asupra rezultatelor dvs. Cu toate elementele majore si minore cu valori de referinta echilibrate la rezultate, nu va lasa nici o indoiala asupra regimului de dozare.
Elemente majore: clorura, sodiu, sulf, magneziu, calciu, potasiu, brom, strontiu si bor
Elemente minore: aluminiu, antimoniu, arsenic, bariu, beriliu, bismut, cadmiu, crom, cobalt, cupru, fier, iod, plumb, litiu, mangan, mercur, molibden, nichel, fosfor, seleniu, siliciu, argint, taliu, staniu , titan, vanadiu si zinc
Software-ul de laborator online va ajuta in interpretarea rezultatelor.
http://lab.atiaquaristik.com/auth/login
- ATI-Aquaristik